Meniscal-Repair

  • In-house development of a system for the minimally invasive refixation of meniscus tears
  • Special foldable anchor for high strength and save and reproducible placement
  • Intuitive one handed use
  • Special needle geometry and low insertion force for minimal tissue injury
  • Developed with orthopedists

 

Go back

PRODUCT DEVELOPMENT

Since 1997 we are developing and producing injection systems and products for medical technology - exclusively in Germany.

Injection systems and medical devices

Since 1997 we are developing and producing injection systems, injection aids and products for the medical industry. We cover with our safety syringes, disposable injectors, mechanical and electrical autoinjectors for self-injection, each with and without connectivity, the entire product range for syringes, cartridges and dual-chamber cartridges.
In addition, /H&B/ Electronic is developing implantation devices and systems for minimally invasive surgery, e.g. All-Inside Meniscal Repair Systems. For more information about the individual developments, please click on Info ...

Please contact us for specific questions via medizintechnik@h-und-b.de !

 

Injector for dual-chamber cartridges

  • In-house development of an injection system with 4-step technology (insertion, injection, dwell time, withdrawal)
  • Design can be adapted to any kind of syringes, cartridges and customer needs
  • Connectivity as an option
  • Safety functions implemented, e.g. activation prevention before complete mixing
  • Mixing by pushing together or twisting the two housing parts
  • The injection process can be adapted to the medicament and safety requirements

Injection procedure

  • Screw on the needle with protective cap
  • Mixing the drug by relative movement of the two housing parts
  • Remove the protective cap
  • Place on injection site and start the injection
  • Injection is perform

 

 

Applicator for implants

  • In-house development of an implantation system for under skin implantation of various implants
  • Cost effective solution with less parts
  • Integrated safety features against inappropriate use
  • Defined implant placement
  • Applicable for example for hormonal implants, RFID-Chips, …
  • Intuitive one handed use
  • Implantation of multiple implants possible

 

Meniscal-Repair

  • In-house development of a system for the minimally invasive refixation of meniscus tears
  • Special foldable anchor for high strength and save and reproducible placement
  • Intuitive one handed use
  • Special needle geometry and low insertion force for minimal tissue injury
  • Developed with orthopedists

 

Injector

  • In-house development of an injection system with 4-step technology (insertion, injection, dwell time, withdrawal)
  • Cost effective solution with less parts
  • Design can be adapted to any kind of syringes, cartridges and customer needs
  • Connectivity as an option
  • The product is ideally suited for self injection
  • The needle is fully covered before and after the injection

Injection procedure

  • Remove the protective cap
  • Place on injection site
  • Start the injection
  • Injection is performed automatically in four steps (insertion, injection, dwell time, withdrawal)
  • Disposal

 

 

Safety Syringe

  • In-house development of an safety syringe for manual operation with 4-step technology (insertion, injection, dwell time, withdrawal)
  • Mechanical assisted needle insertion
  • Constant plunger force
  • Intuitive syringe handling
  • Cost effective solution with less parts
  • Design can be adapted to any kind of syringes, cartridges and customer needs
  • Connectivity as an option
  • The product is ideally suited for self injection
  • The needle is fully covered before and after the injection

Injection procedure

  • Remove the protective cap
  • Place on injection site
  • Press the plunger to the end stop
  • Disposal

 

 

Mechanical Infusion Pump

  • Infusion pump with a new developed mechanic for the administration of a defined medicament amount with adjustable infusion speed
  • Automated de-airing of the syringe and the infuison line
  • High accuracy
  • Fits for different syringes
  • Connectivity as an option e.g. to monitor the filling level

Infusion procedure

  • Insert the filled syringe with the infusion line and de-airing cap
  • Automated de-airing of the syringe and infusion line by closing the cover
  • Removal of the de-airing cap
  • Connect the infusion line to the intravenous access
  • Adjust the infusion speed and duration of infusion
  • Start the infusion
  • Acoustic signal after the infusion is completed

 

 

BETACOMFORT®

  • Advancement of the very successful Betaject Comfort® with 4-step technology (insertion, injection, dwell time, withdrawal)
  • Adjustable insertion depth
  • Manufacturing and distribution since 2012

Injection procedure

  • Reset the mechanic by pushing the handle
  • Insert the syringe
  • Adjust the insertion depth
  • Close the cover
  • Remove protective cap
  • Place on injection site
  • Release the safety catch and start the injection
  • Injection is performed automatically in four steps
  • Acoustic signal after injection is completed
  • Open the cover and dispose the syringe

 

 

Electromechanical Injector

  • Development of an electromechanical autoinjector for a 1.1ml dual-chamber cartridge or a 2.25ml syringe with 4- or 5-step technology (mixing, insertion, injection, dwell time, withdrawal)
  • Adjustable insertion depth and injection speed
  • Connectivity for therapy monitoring
  • The autoinjector is ideally suited for self-injection with therapy monitoring
  • The needle is fully covered before and after the injection

Injection procedure

  • Adjust the insertion depth and injection speed
  • Insert the syringe / dual-chamber cartridge
  • Close the cover
  • Mixing of the medicament (for dual-chamber cartridge only)
  • Remove protective cap
  • Place on injection site and start the injection
  • Injection is performed automatically in four steps
  • Acoustic signal after injection is completed
  • Open the cover and dispose the syringe

 

 

Betaject® Comfort

  • Autoinjector for 2.25ml syringes
  • Increased injection comfort due to the advancement of the Betaject® mechanical solution for a 4-step technology (insertion, injection, dwell time, withdrawal)
  • Indication window (optical display that shows the device status)
  • Safety catch (prevents unintentional activation of the device)
  • Acoustic signal after injection is completed
  • Reduction of skin irritation by dwell time
  • The needle is fully covered before and after the injection
  • Manufacturing and distribution since 2008

Injection procedure

  • Reset the mechanic by pushing the handle
  • Insert the syringe
  • Close the cover
  • Remove protective cap
  • Place on injection site
  • Release the safety catch and start the injection
  • Injection is performed automatically in four steps
  • Acoustic signal after injection is completed
  • Open the cover and dispose the syringe

 

 

Betaject®

  • Adaption of the Beta-Injector S1 to a 1.2ml syringe with 2-step technology (Insertion, injection)
  • Manufacturing and distribution since 2002

Injection procedure

  • Insert the syringe
  • Turn the housing
  • Remove protective cap
  • Place on injection site and start the injection
  • Injection is performed automatically in two steps (insertion, injection)
  • Acoustic signal after injection is completed
  • Turn the housing – reset of the mechanic
  • Dispose the syringe

 

 

Beta-Injector S1

  • Autoinjector for 2ml syringe
  • Development of a mechanical solution for a 2-step technology
  • Manufacturing and distribution since 1999

Injection procedure

  • Insert the syringe
  • Turn the housing
  • Remove protective cap
  • Place on injection site and start the injection
  • Injection is performed automatically in two steps (insertion, injection)
  • Acoustic signal after injection is completed
  • Turn the housing – reset of the mechanic and ejection of the syringe